    Lithium tetrafluoroborate, lithium hexafluorophosphate and lithium perchlorate are used as an electrolyte of a lithium ion secondary battery. In this application, the anions of these salts were analyzed using IC NI-424, an anion analysis column for non-suppressor method. Sample : 20 μL […]

    shodex-image

    Alkyl sulfonic acids were analyzed using IC NI-424, an anion analysis column for non-suppressor method. It was shown that the longer alkyl chains result with stronger the hydrophobic interaction between the packing material and the sample. With longer alkyl chains, retention […]

    shodex-image

    Enoxaparin sodium is a low-molecular-weight heparin with an average molecular weight of about 4,500. It is used as an anticoagulant to inhibit blood coagulation. IC NI-424, an anion analysis column for non-suppressor method, was used to detect sulfate in enoxaparin sodium. […]

    shodex-image

    According to Japanese Testing Methods for Fertilizers (2019*), “6.2.a Ion chromatography method” under “6.2 Chloride” includes both suppressor and non-suppressor methods. The non-suppressor method should be carried out with a column filled with hydrophilic polymethacrylate gel modified with quaternary ammonium […]

    shodex-image

    Ammonium sulfate is a common nitrogen fertilizer. However, during its production process, sulfamic acid and ammonium thiocyanate may form as impurities and they are known to interfere plants germination. According to Japanese Testing Methods for Fertilizers (2016*), “Ion chromatography method” […]

    shodex-image

      Non-suppressor ion chlomatography column, IC NI-424 was used to analyze organic acids. Under this condition, furmaric acid eluetes before oxyalic acid. Sample : 20 µL 1. Acetic acid 20.0mg/L 2. Formic acid 20.0mg/L 3. Malic acid 20.0mg/L 4. Tartaric […]

    shodex-image

      The administrative order of the Ministry of Health, Labour and Welfare #261 (July 22, 2003) specifies the acceptable levels for F–, Cl–, NO2– and NO3–. Their concentrations are measured using ion chromatography. Here, anions in tap water were analyzed […]

    shodex-image

      Seven kinds of anions were detected using IC NI-424 in river water. Sample : River water (Water), 10micro-L 1. H2PO4– 2. F– 3. Cl– 4. NO2– 5. Br– 6. NO3– 7. SO42- Column : Shodex IC NI-424 (4.6mmID*100mm) Eluent […]

    shodex-image

      Four kinds of anions in rain water were analyzed using IC NI-424. Sample : Rain water (Water), 100micro-L 1. Cl– 2. NO2– 3. NO3– 4. SO42-   Column : Shodex IC NI-424 (4.6mmID*100mm) Eluent : 8mM 4-Hydroxybenzoic acid + […]

    shodex-image

    Effects of pH on Retention Time (NI-424) Effects of eluent pH on the elution of each anion using IC NI-424 (an anion analysis column for non-suppressor method) are shown. When the pH of the eluent is increased, the retention time […]