shodex-image

    On March 25th 2020, the Japanese Water Supply Act added chlorate in “Appendix No. 18-2, analysis by LC/MS/MS”. In addition to the use of ethylendiamine as an additive for the collected water sample, the use of sodium thiosulfate solution is […]

    shodex-image

    Under the “Methods Prescribed by the Minister of Health, Labour and Welfare Based on the Provisions of the Ordinance on Water Quality Standards” (MHLW Notification No. 261, July 22, 2003; last amended by Notification No. 95*, March 25, 2020), chlorate […]

    shodex-image

    Simultaneous analysis of water-soluble vitamins (ascorbic acid and pantothenic acid) and sulfite was performed using RSpak KC-811 column for organic acid analysis. Sample : 20 µL 10 μg/mL each (in eluent) 1. Ascorbic acid 2.SO32- (Sodium hydrogen sulfite) 3. Pantothenic acid (Calcium […]

    shodex-image

    Nitrite and ammonium thiocyanate (thiocyanate compounds) are known cause of plant growth disorders. According to Japanese Testing Methods for Fertilizers (2016*), “High-performance liquid chromatography method” under “5.8 Ammonium thiocyanate (thiocyanate compound)” and “5.9 Nitrite” should be carried out with a column […]

    shodex-image

    Carbonate ion is present in virtually all water samples and plays an important role in ion balance. Thus, it is an important task to simultaneously analyze seven common anions (F–, Cl–, NO2–, Br–, NO3–, HPO42- and SO42-) in the presence […]

    shodex-image

    Samples containing more than 10mg/L of Mg2+ and/or 20mg/L of Ca2+ must be pretreated, because those divalent cations form complexes with the eluent and give rise to broad peaks which interfere with the analysis. For pretreatment, samples are passed through a pretreatment […]

    shodex-image

      Organic acids were analyzed using RSpak KC-811. Sample : 1. Citric acid 2. Malonic acid 3. Succinic acid 4. Lactic acid 5. Formic acid 6. Acetic acid Column : Shodex RSpak KC-811 (8.0mmID*300mm) Eluent : 3mM HClO4 aq. Flow […]

    shodex-image

    Sulfurous acid in red wine was analyzed using RSpak KC-811. Sample: Wine (red) 1. SO32-   Column : Shodex RSpak KC-811 (8.0mmI.D. x 300mm) Eluent : 0.5mM HClO4 aq. Flow rate : 1.0mL/min Detector : ECD (Pt electrode) Column temp. […]

    shodex-image

    Silicic acid and boric acid were analyzed using RSpak KC-811. Sample: 100μL (A) Standards 20mg/L each 1. Silicic acid 2. Boric acid (B) Tap water 1. Silicic acid   Column : Shodex RSpak KC-811 (8.0mmI.D. x 300mm) Eluent : 0.5mM […]

    shodex-image

    Sulfurous acid is a weak acid and can be separated by ion exclusion chromatography using RSpak KC-811. (A) is a chromatogram of standards. (B) is a chromatogram of direct injection of diluted wine and only free sulfurous acid is detected […]