
Please use this column with suppressor type ion chromatography system. Anion standards and organic acids were analyzed using IC SI-50 4D (a column for anions analysis). Sample: 20 µL F– 2 mg/L Acetate 10 mg/L Formate 2 mg/L Cl– 3 mg/L NO2– 5 […]

Please use this column with suppressor type ion chromatography system. The National Standards of China GB 8538‑2022*, “National Food Safety Standard – Examination Methods for Drinking Natural Mineral Water,” and GB/T 5750.10‑2023*, “Standard Examination Methods for Drinking Water – Part […]

Please use this column with suppressor type ion chromatography system. The National Standards of China GB 8538‑2022*, “National Food Safety Standard – Examination Methods for Drinking Natural Mineral Water,” and GB/T 5750.10‑2023*, “Standard Examination Methods for Drinking Water – Part […]

*Please use this column with suppressor type ion chromatography system. The effects of column temperature on analysis of seven general inorganic anions using IC SI-50 4D, a column for anions analysis, were studied. Effects of temperature on elution positions of […]

*Please use this column with suppressor type ion chromatography system. The effects of flow rate on analysis of seven general inorganic anions using IC SI-50 4D, a column for anions analysis, were studied. Regardless of the fact that column performance […]

*Please use this column with suppressor type ion chromatography system. IC SI-50 4D, a column for anions analysis, and IC SI-90 4E, its conventional type, were used to compare their performances on rapid analysis of seven general inorganic anions. SI-50 […]

The United States Environmental Protection Agency (EPA) Method 300.1 specifies methods for anion analysis in drinking water. EPA Method 300.1 has two parts. Part A: analysis of common ions and Part B: analysis of inorganic disinfection byproducts. Both uses the […]

Please use this column with a suppressor-type ion chromatography system. IC SI-37 4D is a column for anion analysis using potassium hydroxide aqueous solution as eluent. It can separate common oxyhalides and anions under isocratic conditions. With SI-37 4D, sulfate […]

Please use this column with suppressor type ion chromatography system. The Japanese regulation for “Testing Methods for Fertilizers (2020*)” lists IC SI-90 4E as a suppressor type IC (anion) column for the analysis of sulfuric acid in feeds. In this […]

Please use this column with suppressor type ion chromatography system. Citric acids and aconitic acids which are tricarboxylic acids were analyzed using IC SI-35 4D (a column for anion analysis). In this analysis, citric acid and isocitric acid, cis-aconitic acid […]