Ethanolamines and alkylamines were analyzed using a cation chromatography column, IC YS-50. Each peak should be sharp. Sample : 20 μL 1. Monoethanolamine 10 mg/L 2. Diethanolamine 20 mg/L 3. Triethanolamine 20 mg/L 4. Methylamine 10 mg/L 5. Ethylamine 20 […]

Monovalent and divalent cation standards were analyzed using IC YK-421. Sample : 10μL Li+ 1mg/L Na+ 5mg/L NH4+ 5mg/L K+ 10mg/L Rb+ 30mg/L Cs+ 30mg/L Ca2+ 10mg/L Mg2+ 5mg/L Sr2+ 10mg/L Ba2+ 10mg/L Column : Shodex IC YK-421 (4.6mmI.D. x […]

Cefepime is a type of cephems used to treat various infections. According to the United States Pharmacopeia and the National Formulary (USP 42-NF 37*), “IMPURITIES: Limit of N-Methylpyrrolidine” for “Cefepime for Injection” should be carried out with a 4.0 mm (I.D.) x […]

Trialkylamines were separated using cation chromatography column, IC YK-421. By using the mobile phase stated below, hydrophobic interaction dominates ioninc-interaction. Therefore, shorter chain alkyl amines (less hydrophobic) will elute before longer ones. Sample : Alkylamines 100mg/L, 20?L 1. Trimethylamine, […]

Trialkylammonium were separated using cation chromatography column, IC YK-421. By using the mobile phase used below (high ACN concentration), hydrophobic interaction is suppressed. Thus ioninc-interaction dominates, this makes shorter chain alkylammonium to be retained longer than longer ones. Sample […]

Urea, creatine, creatinine were separated using ion (cation) chromatography column, IC YS-50. Urea and creatinine are known as the final metabolites of nitrogen-containing compounds. Sample: 10μL 1. Urea 0.06% 2. Creatine 0.001% 3. Creatinine 0.001% Column : Shodex IC YS-50 […]

Waste water from electronic production factories may contain hydrophilic polymers. As a waste water model, a sample containing mono- and di-valent cations in the presence of polyethylene glycol (PEG2000) was prepared. Ion chromatography (cation) column, ICYS-50 was used under the […]

Ion chromatography (cation) column, IC YS-50 was used to separate mono- and divalent cations in the presence of albumin. No considerable influence from the presence of albumin was observed. Part of protein (albumin) may be adsorbed on the column, thus […]

Ethylenediamine (0.1% v/v of 50 mg/mL) is added to water samples to prevent HCl production from the reaction between residual chloride and chlorous acid. Ion chromatography (cation) column, IC YS-50 was used to separate mono- and divalent cations in the […]

Monovalent and divalent cations were analyzed using IC YS-50. 18-Crown 6- Ether will make a complex with cations, whose complex building depends on the kind of cations. Therefore, adding 18-Crown-6-Ether is able to control the elusion of cations and improve […]