Choline and acetylcholine were analyzed using IC YS-50, a cation analysis column, under cation exchange mode. If high sensitive analysis is required, LC/MS/MS analysis using HILICpak VC-50 2D, a polymer-based HILIC mode column, is recommended. When VC-50 2D is used, […]

Choline and acetylcholine were analyzed by LC/MS method using HILICpak VC-50 2D, a polymer-based HILIC column. The calibrations curve of choline and acetylcholine show good linearity respectively in the range from 1 to 100mM. Sample : 5μL 5nM each (in […]

Homovanilic acid (HVA) and Vanillylmandelic acid (MVA) are analyzed using Asahipak ES-502N 7C (a column for weak cation exchange chromatography) by UV detection. Sample : HVA and VMA standards Column : Shodex Asahipak ES-502N 7C (7.6mmID*100mm) Eluent : 50mM Bis-Tris […]

Vanillylmandelic acid (VMA) and creatinine in urea are determined by fluorescent detection using three columns, Asahipak ES-502N, GS-320 and NH2P-50 and column-switching method. GS-320 7E is an old type of GS-320 HQ. Sample : a. Diluted urine , b. Standard […]

Homovanilic acid (HVA) and Vanillylmandelic acid (VMA) in urine are analyzed using Asahipak GS-320 7E ( a multimode column ) and electrochemical detection (ECD).GS-320 7E is an old type of GS-320 HQ. Sample : HVA and VMA Column : Shodex […]

Uric acid and creatinine were analyzed using four columns Asahipak ES-502C, ES-502N, GS-310 7G and Asahipak GS-320 7C and column switching method. GS-310 7G is an old type of GF-310 HQ and GS-320 7C is an old type of GF-320 […]

Some metabolites in urine have been added to the health check as special items in Japan recently. From the items, hippuric acid, methylhippuric acid(o-, m-, p-), mandelic acid which are metabolites of toluene, xylene and styrene and creatinine were analyzed […]

Polyamine and acetylated derivatives were analyzed using Asahipak ODP-50 4E (a column for reversed-phase chromatography) with alkaline eluent. Sample : 1. Putrescine 2. Acetylputrescine 3. Cadaverine 4. Spermidine 5. Acetylcadaverine 6. N1-Acetylspermidine 7. N8-Acetylspermidine 8. Spermine 9. Acetylspermine […]

Polyamines, also known as putrid or fixed amines, in foods are mainly generated as the result of denaturation by enzymes accompanying the fermentation or decomposition. Formerly, such polyamines were analyzed by fluorescence derivatization using the precolumn or postcolumn method. […]

Polyamines were analyzed by on-column derivertization using Asahipak ODP-50 4D. Refer to Instruments for On-Column Derivetization Sample : 10micro-LHistamine(Him) , Diethylenetriamine(Det:I.S.) , Tyramine(Tym) , 1,3-Diaminopropane(Dap)Putrescine(Put) , Spermidine(Spd) , Spermine(Spm) , Cadaverine(Cad) Column : Shodex Asahipak ODP-50 4D (4.6mmID*150mm) Eluent : […]