shodex-image

    According to the United States Pharmacopeia and the National Formulary (USP-NF 2021 Issue 1*), under “IMPURITIES: Limit of Ethylene Glycol and Diethylene Glycol” in “Polyethylene Glycol 3350”, analysis should be carried out with a column with L89 packing material and […]

    shodex-image

    Diethylene glycol (DEG) and ethylene glycol (EG) may become contaminates through improper manufacturing processes of raw materials or through contaminated solvents and excipients used in certain product productions. In April 2023, the U.S. Food and Drug Administration (FDA) issued a […]

    shodex-image

    Resveratrol is a type of polyphenol found primarily in grape and peanut skins. Resveratrol has antioxidant effects and is expected to have effects such as anti-aging, prevention of diabetes, and improvement of blood pressure. In this application, we analyzed resveratrol […]

    shodex-image

    Five glycols were analyzed using SUGAR SP0810, a ligand exchange mode column. With a size exclusion mode column, the glycols elute in the order of bigger to smaller molecular weight size. Meanwhile, with SP0810, the glycols elute in the order […]

    shodex-image

    Six kinds of Ketones were analyzed using RSpak DS-413 (a column for reversed phase chromatography). Sample : 1. Acetone 500micro-g/mL 2. Methyl ethyl ketone, 2-Butanone 500micro-g/mL 3. Diethyl ketone, 3-Pentanone 500micro-g/mL 4. Di-n-propyl ketone, 4-Heptanone 500micro-g/mL 5. Butylpropylketone, 4-Octanone 1000micro-g/mL […]

    shodex-image

    The following alcohols are used in cosmetics as moisturizing agents. The saccharide analysis column SUGAR SC1211 was used here to perform the simultaneous analysis of as many as 5 moisturizing compounds. SC1211 is suitable for the analysis of multivalent alcohols […]

    shodex-image

    Rare sugars are known to carry out various biological functions and are used in a research setting for medical, food, and cosmetics applications. In this application, rare sugars psicose and allose were simultaneously analyzed with the SUGAR SP0810 saccharide analysis […]

    shodex-image

    SUGAR SH1011 was used to analyze glycerin and glyceric acid. Sample : 0.1% each, 10μL 1. Glyceric acid 2. Glycerin, Glycerol   Column : Shodex SUGAR SH1011 (8.0mmI.D. x 300mm) Eluent : 2mM H2SO4 aq. Flow rate : 0.6mL/min Detector […]

    shodex-image

    Aliphatic alcohols were analyzed using SUGAR SH1011 and SH1821. Comparing the two chromatograms, the peak shapes with SH1011 are better than those with SH1821. Sample : 1. Methyl alcohol 2. Ethyl alcohol 3. Isopropyl alcohol 4. n-Propyl alcohol 5. tert-Butyl […]

    shodex-image

    Aliphatic alcohols were analyzed using RSpak DE-613 (a column for reversed phase chromatography). Sample : 1. Ethylene glycol 2. Methyl alcohol 3. Ethyl alcohol 4. Isopropyl alcohol 5. n-Propyl alcohol 6. tert-Butyl alcohol 7. sec-Butyl alcohol 8. n-Butyl alcohol Column […]