shodex-image

    The effects of organic solvent was analyzed with a polymer-based HILIC column, Asahipak NH2P-50 4B. The analysis was carried under isocratic mode with different organic solvent ratios. The concentration of acetonitrile in the eluent and the retention time (tR) was […]

    shodex-image

    GABA (γ-aminobutyric acid) is a functional ingredient in foods and has blood pressure suppressing and relaxing effects. It is one of the compounds registered as the Japanese functional ingredient in many numbers. In this application, a commercial supplement containing GABA was […]

    shodex-image

    Theanine is a kind of amino acid contained in tea and has mainly anti-stress and relaxation effects. The analysis of theanine in commercially available supplements was performed in HILIC mode using Asahipak NH2P-50 4E. A calibration curve with high linearity […]

    shodex-image

    Theanine is a type of amino acid which is contained in tea, and is a component related to umami and sweetness. In addition, theanine has reported relaxation effects such as improving sleep quality. Here, theanine as well as various amino […]

    shodex-image

    HILICpak VC-50 2D is a polymer-based amino HILIC column that was used to analyze 20 amino acids. This method does not require the use of derivatization or ion-pair reagents. The result showed basic amino acids were separated well and tend […]

    shodex-image

    Amino acids were analyzed using IC YS-50 for cations. YS-50 is packed with polyvinyl alcohol with carboxyl functional group. Amino acids are separated by reversed-phase mode and ionic interaction, as NN-814 column does Alanine and Glycine elute at the same […]

    shodex-image

    As RSpak NN-814 is packed with polyhydroxymethacrylate bonded with trace amounts of sulfo groups, the main separation mode is the reversed phase mode. However, due to the sulfo groups, ion interaction also works. Acidic amino acids, such as aspartic acid, […]

    shodex-image

      Amino acid standards are analyzed using CXpak P-421S.  Seventeen kinds of amino acids were separated and detected with the ninhydrine reaction.  The total analytical was within 50 minutes. Sample : 0.1µM each, 100µL 1. Asp 2. Thr 3. Ser […]

    shodex-image

      Carcinogenic tryptophan pyrolysis products were analyzed using Asahipak ES-502C 7C (a column for weak cation exchange chromatography). Sample : Trp-P-1 Trp-P-2 Column : Shodex Asahipak ES-502C 7C (7.6mmID*100mm) Eluent : 20mM H3PO4(pH2.0)/CH3CN=90/10 Flow rate : 1.0mL/min Detector : Fluorescence […]