shodex-image

    Fatty acids are compounds where a hydrocarbon chain is attached to a carboxyl group. They can be classified into saturated fatty acids (having no double bonds between carbons) and unsaturated fatty acids (having double bonds). In this application, eight saturated […]

    shodex-image

    PFAS stands for per- and polyfluoroalkyl substances. They are hardly decomposed in the environment, thus its persistence in the environment and accumulation in living organisms are concerned. In this application, PFAS with a terminal carboxyl group and alkyl chains of […]

    shodex-image

    The effects of sample preparation solution composition on HILIC mode sugar separation were studied with a polymer-based amino column, Asahipak NH2P-50 4E. The eluent used was H2O/CH3CN = 25/75. It was observed that the more deviation of the sample preparation […]

    shodex-image

    The effects of sample injection volume on HILIC mode sugar separation were studied with a polymer-based amino column, HILICpak VG-25 4D. The sample was dissolved in water and the sugar load was kept constant for all injection volumes. It was […]

    shodex-image

    The effects of sample preparation solution composition on HILIC mode sugar separation were studied with a polymer-based amino column, HILICpak VG-25 4D. The eluent used was H2O/CH3CN = 20/80. It was observed that the more deviation of the sample preparation […]

    shodex-image

    This application introduces a separation of inositol polyphosphates using a polymer-based amino column, HILICpak VG-50 2D, with a triple quadrupole (QQQ) mass spectrometry (LC-MS/MS). Diphosphoinositol pentakisphosphate (IP7) is biosynthesized from inositol hexakisphosphate (phytic acid; IP6) through intracellular kinases. Accumulation of […]

    shodex-image

    A new member of the VG series, VG-25 4D, is packed with 2.5 μm packing material, smaller than the packing material used in the existing product, VG-50 4D. VG-25 4D showed significantly higher theoretical plate number on all four sugars […]

    shodex-image

    Please read the column cleaning method for your column. HILICpak VG-25 and VG-50 series For an efficient cleaning, reverse the flow direction. Flow rate during the cleaning Product name VG-25 4D VG-25 2B VG-50 4D VG-50 4E VG-50 2D Flow […]

    shodex-image

    HILICpak VN-50 4D, a hydrophilic interaction chromatography (HILIC) column modified with diol functional group was coupled with an ICPMS for the separation analysis of trivalent chromium (Cr(III)) and hexavalent chromium (Cr(VI)). In this application, the eluent used has a high […]

    shodex-image

    A unit called dextrose equivalent (DE) is sometimes used to indicate the degree of polymerization (DP) for starches. DE=0 indicates the state of starch, while when the starch is hydrolyzed and its molecular weight decreases, the DE value increases. Titration […]