shodex-image

    GF-HQ Polymer-based SEC columns with high solvent durability Works well with both aqueous and organic solvents (Standard columns) [Housing material: SUS] Product code Product name Plate number (TPN/column) Particle size (μm) Column size (mm) I.D. x Length F7600000 Asahipak GF-210 HQ […]

    shodex-image

    The Japanese Industrial Standards (JIS) K0450-70-10 states the “Test Method for Perfluorooctanesulfonate (PFOS) and Perfluorooctanoate (PFOA) in Industrial Water and Factory Wastewater” (Established March 22, 2011) includes “Annex JC (Informative): Measurement Conditions for Organic Fluorine Compounds with Different Carbon Chain […]

    shodex-image

    Poly(sodium methacrylate) was analyzed using Asahipak GF-7M HQ, an Aqueous/Organic (multi-solvent use) SEC column. Sample : 0.2 % each, 30 µLPoly(sodium methacrylate) Column : Shodex Asahipak GF-7M HQ (7.5 mm I.D. x 300 mm) Eluent : 50 mM Na2HPO4 aq./CH3CN=90/10 […]

    shodex-image

    PFAS stands for per- and poly-fluoroalkyl substances. They are hardly decomposed in the environment and contain substances that are subject to the Stockholm Convention on Persistent Organic Pollutants (POPs). Its persistence in the environment and accumulation in living organisms are […]

    shodex-image

    Perfluorooctanesulfonic acid (PFOS) and Perfluorooctanoic acid (PFOA) rarely decompose in the natural environment and thus their persistence in the environment and accumulations in living organisms are problems to be considered. They are subjects of the Stockholm Convention on Persistent Organic […]

    shodex-image

    ATP and its related substances in fish and shellfish were analyzed using Asahipak GS-320 HQ, a multimode column. Quantification of ATP and its related substances provide a quantitative evaluation of seafood’s’ freshness, as endogenous enzymes degrade ATPs in dead seafoods […]

    shodex-image

    Peptides in extract from waste water sludge were analyzed using Asahipak GS-320 7G ( a multimode column ). GS-320 7G is an old type of GS-320 HQ. Sample : Peptides in extract from waste water sludgeAcetoneAngiotensin IAngiotensin IIIDextranInsulinMyoglobinOvalbumin Column : […]

    shodex-image

    Crude pronase E was analyzed using Asahipak GS-320 7G ( a multimode column ). GS-320 7G is an old type of GS-320 HQ. Sample : Crude pronase E Column : Shodex Asahipak GS-320 7G (7.6mmID*500mm) Eluent : 1/15M KH2PO4 + […]

    shodex-image

    Endorphins were analyzed using Asahipak GS-320 HQ ( a multimode column ). Sample : 1. beta-Endorphin 2. alpha-Endorphin 3. gamma-Endorphin Column : Shodex Asahipak GS-320 HQ (7.6mmID*300mm) Eluent : 0.1% TFA/CH3CN=95/5 Flow rate : 0.8mL/min Detector : UV(210nm) Column temp. […]

    shodex-image

    Chymotrypsin-hydrolysated peptides of ascidian 29K protein were analyzed using Asahipak GS-320 7G ( a multimode column ). GS-320 7G is an old type of GS-320 HQ. Sample : A. Ser-CMC-Ser-Glu-Phe, B. Asp-Ser-Phe, C. Ala-Tyr, D. Thr-Ser-Ser-Leu, E. Ser-Gln-Asp-Trp (1) Preliminary […]