According to the Japanese Ingredient Standards for Foods for Specified Health Uses (FOSHU), the Quantitative Method for “Polydextrose” specifies the use of a column packed with polystyrene-divinylbenzene cation- and anion-exchange resins (stainless steel column, 7 – 9 mm I.D. and […]

According to the United States Pharmacopeia and the National Formulary (USPNF 2025 Issue 1*), “Molecular Weight Limit” for “Hydrogenated Polydextrose” should be carried out with a column filled with L39 packing material. The OHpak SB-804 HQ, a column filled with […]

According to the United States Pharmacopeia and the National Formulary (USPNF 2025 Issue 1*), “Molecular Weight Limit” for “Polydextrose” should be carried out with a column filled with L39 packing material. The OHpak SB-804 HQ, a column filled with L39 […]

Maltodextrin is a polysaccharide and can be obtained by hydrolysing starch. In this application, we used a new member of polymer-based amino column, HILICpak VG-25 4D, to analyze maltodextrins with Dextrose Equivalent (DE*) 13-17. Gradient elution is generally used to […]

Ferric carboxymaltose is used for the treatment of anemia. It was analyzed using OHpak SB-800 HQ series columns, columns for aqueous SEC (GFC). Sample: 25 µL Ferric carboxymaltose 2.5 %(w/v) Columns : Shodex OHpak SB-G 6B (6.0 mm I.D. x […]

Dietary fiber has preventive effects on dyslipidemia, constipation, obesity, etc. In Japan, indigestible dextrin is approved to be labeled as a Food for Specified Health Uses (FOSHU). This labeling system was started in 1991. The Japanese Director-General of the Consumer […]

Dietary fiber has preventive effects on dyslipidemia, constipation, obesity, etc. In Japan, indigestible dextrin is approved to be labeled as a Food for Specified Health Uses (FOSHU). This labeling system was started in 1991. The Japanese Director-General of the Consumer […]

According to the United States Pharmacopeia and the National Formulary (USP 43-NF 38*), “ASSAY” for “Propylene Glycol Monocaprylate” should be carried out with a 7.0 mm (I.D.) x 60 cm (length) column filled with L21 packing material. Use of two GPC […]

Heparin sodium was analyzed using PROTEIN KW-804, a column for aqueous SEC (GFC). Sample : 20 μL Heparin sodium, 5 mg/mL Columns : Shodex PROTEIN KW-804 (8.0 mmI.D. x 300 mm) Eluent : 0.1 M CH3COONH4 + 0.2 % […]

Heparin sodium was analyzed using PROTEIN KW-804, a column for aqueous SEC (GFC). Sample : 20 μL Heparin sodium, 5 mg/mL Columns : Shodex PROTEIN KW-804 (8.0 mmI.D. x 300 mm) Eluent : 0.1 M CH3COONH4 + 0.2 % […]