shodex-image

    Shodex HILICpak VG-25 2B is a compact semi-micro HILIC column for rapid sugar analysis. In this application, mannose and lactose were separated in less than 6 minutes using isocratic acetonitrile/water conditions, demonstrating fast analysis on the 50 mm column format. […]

    shodex-image

    Shodex HILICpak VG-25 2B is a semi-micro HILIC column designed for the analysis of sugars and sugar alcohols. The column has a 2.0 mm I.D. × 50 mm format with 2.5 µm polymer-based amino-modified packing material. In this application, fructose, […]

    shodex-image

    Acetonitrile is commonly used in HILIC applications; however, it is classified as a hazardous substance. In contrast, ethanol is known to have lower toxicity than many other organic solvents. In this application, sugars were analyzed using commercially available 95% ethanol […]

    shodex-image

    The National Standards of China GB/T 20882.1-2025*, Quality requirements for starch sugar – Part 1: Edible dextrose, lists two HPLC methods for the determination of glucose content. *The version at the time of the application acquisition. Chromatographic Condition 1 A […]

    shodex-image

    The Chinese Pharmacopoeia 2025 Edition*, Part IV, the monograph for Lactose, analysis by high‑performance liquid chromatography specifies the use of a column packed with amino silica or amino polymer gel. HILICpak VG-50 4E column confirmed the requirement was met. System […]

    shodex-image

    Since charged aerosol detectors (CAD) measure analytes as particles, components eluting from columns can significantly affect the baseline. A polymer-based amino column Asahipak NH2P-50 series releases a very few components from the column, resulting in a low noise level and a […]

    shodex-image

    The Chinese Pharmacopoeia 2025 Edition*, Part IV, the high‑performance liquid chromatography method for “Trehalose” specifies the use of a column packed with styrene–divinylbenzene copolymer–based cation‑exchange resin in the sodium form (or hydrogen form). SUGAR KS-801 column confirmed the requirements were […]

    shodex-image

    Since charged aerosol detectors measure analytes as particles, components eluting from columns can significantly affect the baseline. A polymer-based amino column HILICpak VG-50 series releases a very few components from the column, resulting in a low noise level and a […]

    shodex-image

    Since charged aerosol detectors measure analytes as particles, components eluting from columns can significantly affect the baseline. A polymer-based amino column HILICpak VG-25 series releases a very few components from the column, resulting in a low noise level and a […]

    shodex-image

    1. Introduction The analysis of small saccharides—including fructose, glucose, galactose, sucrose, lactose, and maltose—is a critical component of quality control in food and beverage manufacturing, nutrition analysis, and clinical research. However, saccharides present unique chromatographic challenges. They lack strong chromophores, […]