
Ferric carboxymaltose is used for the treatment of anemia. It was analyzed using OHpak SB-800 HQ series columns, columns for aqueous SEC (GFC). Sample: 25 µL Ferric carboxymaltose 2.5 %(w/v) Columns : Shodex OHpak SB-G 6B (6.0 mm I.D. x […]

The polystyrene oligomers’ separation performance of GPC FP-2002, a column for organic SEC (GPC), is compared with that of other manufacturer’s rapid separation columns (molecular weight exclusion limits (ML):5,000 and 1,000). Even FP-2002 has higher exclusion limit than the competitor’s […]

The separation performance of GPC FP-2002, a column for organic SEC (GPC) is compared with that of other manufacturer’s rapid separation columns (molecular weight exclusion limits (ML): 5,000 and 1,000). FP-2002 has a larger pore volume than other manufacturer’s columns […]

The standard flow rate of the packed column GPC FP-2002 for organic solvent-based SEC (GPC) is 10 mL/min. We have investigated the flow rate dependency of phthalate esters recycling separation. Even at the maximum usable flow rate of 20 mL/min, […]

The calibration curve of the column GPC FP-2002 for organic solvent-based SEC (GPC) is shown. Sample : Polystyrene 1 mL each Column : Shodex GPC FP-2002 (20.0 mm I.D. x 600 mm) Eluent : CHCl3 Flow rate : 10.0 […]

GPC FP-2002 is a column suitable for rapid organic solvent SEC(GPC) separation. Phthalate esters were used to compare recycled separations with other manufacturer’s rapid preparative column (exclusion limit molecular weight (ML): 5,000). Since the FP-2002 has a slower slope of […]

Epoxy resin was analyzed using GPC K-803L, an organic SEC (GPC) column. Although epoxy resin is usually analyzed with THF eluent, it can also be analyzed with chloroform as the eluent. *Sales of the product used in this application are […]

Poly(o-cresyl glycidyl ether)-co-formaldehyde was analyzed using Asahipak GF-310 HQ (a multi-solvent GPC column) . Sample : Poly(o-cresyl glycidyl ether)-co-formaldehyde Column : Shodex Asahipak GF-310 HQ (7.6mmID*300mm) Eluent : CHCl3 Flow rate : 0.5mL/min Detector : UV(254nm) Column temp. : […]

Polylactic acid which is one of the biodegradable polymer was analyzed using GPC LF-604, a column for organic SEC (GPC). Sample : 0.2% Polylactic acid, 50μL Columns : Shodex GPC LF-604 (6.0mmI.D. x 150mm) x 2 Eluent : CHCl3 […]

Liquid paraffin was analyzed using GPC KF-401HQ, a semi-micro column for organic SEC (GPC). Sample : 1% Liquid paraffin, 5μL Column : Shodex GPC KF-401HQ (4.6mmI.D. x 250mm) Eluent : CHCl3 Flow rate : 0.3mL/min Detector : Shodex RI(small […]