Calibration curves for GPC HK-400 series, organic SEC (GPC) columns for ultra-rapid analysis, using PEG/PEO are shown. Sample : Poly(ethylene glycol) Poly(ethylene oxide) Tetraethylene glycol Columns : Shodex GPC HK-400 series (4.6 mm I.D. x 150 mm each) Eluent […]

Calibration curves for GPC HK-400 series, organic SEC (GPC) columns for ultra-rapid analysis, using PEG/PEO are shown. Sample : Poly(ethylene glycol) Poly(ethylene oxide) Tetraethylene glycol Columns : Shodex GPC HK-400 series (4.6mmI.D. x 150mm each) Eluent : DMF Flow […]

Calibration curves for GPC KD-800 series using poly(methyl methacrylate) are shown. Sample : Poly(methylmethacrylate) Columns : Shodex GPC KD-800 series (8.0mmI.D. x 300mm) Eluent : DMF Flow rate : 1.0mL/min Detector : Shodex RI Column temp. : 40°C

Calibration curve for GPC LF-804 using PEG/PEO is shown. Sample : Poly(ethylene oxide) Poly(ethylene glycol) Tetraethylene glycol Column : Shodex GPC LF-804 (8.0mmI.D. x 300mm) Eluent : DMF Flow rate : 0.7mL/min Detector : Shodex RI Column temp. : […]

Calibration curves (PEG, PEO) for OHpak LB-800 series using PEG/PEO are shown. Sample : Poly(ethylene glycol) Poly(ethylene oxide) Tetraethylene glycol Diethylene glycol Columns : Shodex OHpak LB-800 series (8.0 mm I.D. x 300 mm each) Eluent : DMF Flow […]

Cellulose acetate is cellulose whose hydroxyl group is partially or perfectly acetylated, and is used for coating agent or sustained release agent. The solubility of Cellulose acetate into water is very low, and it is easily solve into DMF or […]

Copovidone is co-polymer made by N-vinyl-2- pyrolidone and vinyl acetate. It is used for coating agent or binder. Copovidone is insoluble in water, so dimethyl formamide (DMF) was used as the eluent. In this application, Even though DMF is used […]

Organic solvent SEC (GPC) column, GPC KD-806M was used to analyze cellulose. Sample preparation (to dissolve cellulose into solvent) is highly dependent on the type of solvent and characteristics of the sample (crystallization, MW). Some may take up to 60 […]

Comparison of KD-800 and SB-800 HQ Vinylidene chloride acrylonitrile copolymer was analyzed. Compared with the GPC KD-800 columns, the OHpak SB-800 HQ columns perform better over a molecular weight range. Sample: Vinylidene chloride acrylonitrile copolymer Columns : Shodex GPC […]

Phenol formaldehyde resin was analyzed using OHpak SB-800 HQ columns and GPC KD-800 columns. Sample : Phenol formaldehyde resin Columns : Shodex GPC KD-804 + KD-802.5, OHpak SB-804 HQ + SB-802.5 HQ (8.0mmI.D. x 300mm each) Eluent : 5mM […]