shodex-image

    Calibration curves for GPC HK-400 series, organic SEC (GPC) columns for ultra-rapid analysis, using PEG/PEO are shown. Sample : Poly(ethylene glycol) Poly(ethylene oxide) Tetraethylene glycol   Columns : Shodex GPC HK-400 series (4.6 mm I.D. x 150 mm each) Eluent […]

    shodex-image

    Calibration curves for GPC HK-400 series, organic SEC (GPC) columns for ultra-rapid analysis, using PEG/PEO are shown. Sample : Poly(ethylene glycol) Poly(ethylene oxide) Tetraethylene glycol   Columns : Shodex GPC HK-400 series (4.6mmI.D. x 150mm each) Eluent : DMF Flow […]

    shodex-image

    Calibration curves for GPC KD-800 series using poly(methyl methacrylate) are shown. Sample : Poly(methylmethacrylate)   Columns : Shodex GPC KD-800 series (8.0mmI.D. x 300mm) Eluent : DMF Flow rate : 1.0mL/min Detector : Shodex RI Column temp. : 40°C

    shodex-image

    Calibration curve for GPC LF-804 using PEG/PEO is shown. Sample : Poly(ethylene oxide) Poly(ethylene glycol) Tetraethylene glycol   Column : Shodex GPC LF-804 (8.0mmI.D. x 300mm) Eluent : DMF Flow rate : 0.7mL/min Detector : Shodex RI Column temp. : […]

    shodex-image

    Calibration curves (PEG, PEO) for OHpak LB-800 series using PEG/PEO are shown. Sample : Poly(ethylene glycol) Poly(ethylene oxide) Tetraethylene glycol Diethylene glycol   Columns : Shodex OHpak LB-800 series (8.0 mm I.D. x 300 mm each) Eluent : DMF Flow […]

    shodex-image

    Cellulose acetate is cellulose whose hydroxyl group is partially or perfectly acetylated, and is used for coating agent or sustained release agent. The solubility of Cellulose acetate into water is very low, and it is easily solve into DMF or […]

    shodex-image

    Copovidone is co-polymer made by N-vinyl-2- pyrolidone and vinyl acetate. It is used for coating agent or binder. Copovidone is insoluble in water, so dimethyl formamide (DMF) was used as the eluent. In this application, Even though DMF is used […]

    shodex-image

    Organic solvent SEC (GPC) column, GPC KD-806M was used to analyze cellulose. Sample preparation (to dissolve cellulose into solvent) is highly dependent on the type of solvent and characteristics of the sample (crystallization, MW). Some may take up to 60 […]

    shodex-image

    Comparison of KD-800 and SB-800 HQ Vinylidene chloride acrylonitrile copolymer was analyzed. Compared with the GPC KD-800 columns, the OHpak SB-800 HQ columns perform better over a molecular weight range. Sample: Vinylidene chloride acrylonitrile copolymer   Columns : Shodex GPC […]

    shodex-image

    Phenol formaldehyde resin was analyzed using OHpak SB-800 HQ columns and GPC KD-800 columns. Sample : Phenol formaldehyde resin   Columns : Shodex GPC KD-804 + KD-802.5, OHpak SB-804 HQ + SB-802.5 HQ (8.0mmI.D. x 300mm each) Eluent : 5mM […]