shodex-image

    Vitamin D2 and D3 were separated using Asahipak ODP-50 6E, a polymer-based reversed phase column. ODP-50 has a wide pH range and can be washed with an aqueous solution of acid or alkali, so it is a highly durable column […]

    shodex-image

    Carotene is a type of carotenoid that has vitamin A action in the human bodies. C18U 2D was used to analyze α-carotene and β-carotene. The analysis was completed within 10 minutes. α-carotene and β-carotene were detected in a commercial 100 […]

    shodex-image

    Ten kinds of water-soluble vitamins were simultaneously analyzed using RSpak DE-413, a polymer-based reversed phase chromatography column. Note: we recommend 2X DE-413 in tandem for better simultaneous separation. Sample : 10 μL   1. Vitamin B1 200 µM 2. Vitamin […]

    shodex-image

    This shows an analysis example of vitamin B12 together with creatinine and urea by reversed phase mode using OHpak SB-802.5 HQ. Sample : 10 μL 1. Creatinine 100 μg/mL 2. Urea 2000 μg/mL 3. Vitamin B12 200 μg/mL *dissolved in eluent   […]

    shodex-image

    According to the United States Pharmacopeia and the National Formulary (USP 40-NF 35*), “ASSAY” for “Ascorbic Acid Injection” should be carried out with a column filled with L39 packing material. The RSpak DM-614, a column filled with L39 packing material, […]

    shodex-image

    Pantothenic acid and ascorbic acid were analyzed by HILICpak VT-50 2D under the conditions of HILIC mode LC/MS. Sample : 100ng/mL, 10μL 1. Pantothenic acid (Vitamin B5) 2. Ascorbic acid (Vitamin C)   Column : Shodex HILICpak VT-50 2D (2.0mmI.D. […]

    shodex-image

    Polymer-based amino column, Asahipak NH2P-50 4E, was used to analyze water-soluble vitamins under HILIC mode. Six water-soluble vitamins were separated within 5 minutes. [Note] This analysis requires column equilibration. For column equilibration: First, introduce 60 mM phosphoric acid at 0.5 […]

    shodex-image

      Ascorbic acid and uric acid in liquor cerebronspinalis were analyzed using Asahipak GS-320 7E ( a multimode column ) and an electrochemical detector (ECD). GS-320 7E is an old type of GS-320 HQ. Sample : Uric acid Ascorbic acid […]

    shodex-image

      Ascorbic acid in urine was analyzed using Asahipak GS-320 7E (a multimode column). GS-320 7E is an old type of GS-320 HQ.   Sample : Urine 1. Glucose 2. Diketoglonic acid 3. Diketogluconic acid 4. Dehydroisoascorbic acid 5. Dehydroascorbic […]

    shodex-image

    Asahipak ODP-50 4E was used for the simultaneous analysis of fat-soluble vitamins. Good calibration curves were obtained for them. Sample: 20μL 1. Vitamin K3 1.5μg/mL 2. Vitamin A 1.0IU/mL(0.3μg/mL) 3. Vitamin A acetate 0.5IU/mL(1.9μg/mL) 4. Vitamin D2 13.2IU/mL(0.3μg/mL) 5. Vitamin […]