HILICpak VG-50
(Standard columns)[Housing material: SUS]
VG-50 |
|
---|---|
VT-50 |
|
New VC-50 |
· Modified carboxyl group is suitable for cationic substance analysis including amines
|
New VN-50 |
· The modified diol groups on the packing material create the HILIC mode
|
Product code | Product name | Plate number (TPN/column) |
Functional group |
Particle size (μm) |
Size (mm) I.D. x Length |
---|---|---|---|---|---|
F7630200
|
HILICpak VG-50 4D |
≥ 5,500
|
Amino
|
5
|
4.6 x 150
|
F7630100
|
HILICpak VG-50 4E |
≥ 7,500
|
Amino
|
5
|
4.6 x 250
|
F6711100
|
HILICpak VG-50G 4A | (guard column) |
Amino
|
5
|
4.6 x 10
|
Product name |
Max. usable pressure (MPa) |
Usual flow rate (mL/min) |
Max. usable flow rate (mL/min) |
Usable temp. range (°C) |
Usable pH range | Shipping solvent |
---|---|---|---|---|---|---|
VG-50 4D |
10
|
0.5 to 1.0
|
1.5
|
4 to 60
|
2 to 13
|
H2O/CH3CN=20/80
|
VG-50 4E |
15
|
0.5 to 1.0
|
1.5
|
4 to 60
|
2 to 13
|
H2O/CH3CN=20/80
|
VG-50G 4A |
–
|
0.5 to 1.0
|
1.5
|
4 to 60
|
2 to 13
|
H2O/CH3CN=20/80
|
[Housing material: PEEK]
Product code | Product name | Plate number (TPN/column) |
Functional group |
Particle size (μm) |
Size (mm) I.D. x Length |
---|---|---|---|---|---|
F7630300
|
HILICpak VG-50 2D |
≥ 3,500
|
Amino
|
5
|
2.0 x 150
|
F6711200
|
HILICpak VG-50G 2A |
(guard column)
|
Amino
|
5
|
2.0 x 10
|
Product name |
Max. usable pressure (MPa) |
Usual flow rate (mL/min) |
Max. usable flow rate (mL/min) |
Usable temp. range (°C) |
Usable pH range | Shipping solvent |
---|---|---|---|---|---|---|
VG-50 2D |
15
|
0.1 to 0.2
|
0.45
|
4 to 60
|
2 to 13
|
H2O/CH3CN=15/85
|
VG-50G 2A |
–
|
0.1 to 0.2
|
0.45
|
4 to 60
|
2 to 13
|
H2O/CH3CN=15/85
|
Eluents:
Aqueous solutions of Acetonitrile (or Methanol) at any ratio, is used as eluent.
Any salts soluble in the solution above are available.HILICpak VT-50
(Standard column)[Housing material: PEEK]
Product code | Product name | Plate number (TPN/column) |
Functional group |
Particle size (μm) |
Size (mm) I.D. x Length |
---|---|---|---|---|---|
F7630400
|
HILICpak VT-50 2D |
≥ 4,500
|
Quaternary ammonium
|
5
|
2.0 x 150
|
F6711300
|
HILICpak VT-50G 2A |
(guard column)
|
Quaternary ammonium
|
5
|
2.0 x 10
|
Product name | Max. usable pressure (MPa) |
Usual flow rate (mL/min) |
Max. usable flow rate (mL/min) |
Usable temp. range (°C) |
Usable pH range | Shipping solvent |
---|---|---|---|---|---|---|
VT-50 2D |
10
|
0.2 to 0.3
|
0.5
|
4 to 60
|
2 to 13
|
25mM HCOONH4 aq.
/CH3CN=15/85 |
VT-50G 2A |
–
|
0.2 to 0.3
|
0.5
|
4 to 60
|
2 to 13
|
25mM HCOONH4 aq.
/CH3CN=15/85 |
Eluents:
Aqueous solutions of Acetonitrile (or Methanol) at any ratio, is used as eluent.
Any salts soluble in the solution above are available.HILICpak VC-50
(Standard column)[Housing material: PEEK]
Product code | Product name | Plate number (TPN/column) |
Functional group |
Particle size (μm) |
Size (mm) I.D. x Length |
---|---|---|---|---|---|
F7630700
|
HILICpak VC-50 2D |
≥ 3,500
|
Carboxyl
|
5
|
2.0 x 150
|
F6711600
|
HILICpak VC-50G 2A |
(guard column)
|
Carboxyl
|
5
|
2.0 x 10
|
Product name | Max. usable pressure (MPa) |
Usual flow rate (mL/min) |
Max. usable flow rate (mL/min) |
Usable temp. range (°C) |
Usable pH range | Shipping solvent |
---|---|---|---|---|---|---|
VC-50 2D |
10
|
0.1 to 0.3
|
0.5
|
4 to 60
|
2 to 12
|
H2O
|
VC-50G 2A |
–
|
0.1 to 0.3
|
0.5
|
4 to 60
|
2 to 12
|
H2O
|
Eluents:
Aqueous solutions of Acetonitrile at any ratio, is used as eluent.*
Any salts soluble in the solution above are available.
*Methanol is not available as the eluent. Other organic solvents including Methanol are not guaranteed as the eluent.HILICpak VN-50
(Standard columns)[Housing material: PEEK]
Product code | Product name | Plate number (TPN/column) |
Functional group |
Particle size (μm) |
Size (mm) I.D. x Length |
---|---|---|---|---|---|
F7630500
|
HILICpak VN-50 4D |
≥ 10,000
|
Diol
|
5
|
4.6 x 150
|
F6711400
|
HILICpak VN-50G 2A |
(guard column)
|
Diol
|
5
|
4.6 x 10
|
F7630600
|
HILICpak VN-50 2D |
≥ 3,500
|
Diol
|
5
|
2.0 x 150
|
F6711500
|
HILICpak VN-50G 2A |
(guard column)
|
Diol
|
5
|
2.0 x 10
|
Product name | Max. usable pressure (MPa) |
Usual flow rate (mL/min) |
Max. usable flow rate (mL/min) |
Usable temp. range (°C) |
Usable pH range | Shipping solvent |
---|---|---|---|---|---|---|
VN-50 4D |
10
|
0.3 to 1.0
|
1.5
|
4 to 60
|
2 to 13
|
H2O/CH3CN=25/75
|
VN-50G 4A |
–
|
0.3 to 1.0
|
1.5
|
4 to 60
|
2 to 13
|
H2O/CH3CN=25/75
|
VN-50 2D |
10
|
0.05 to 0.3
|
0.5
|
4 to 60
|
2 to 13
|
H2O/CH3CN=25/75
|
VN-50G 2A |
–
|
0.05 to 0.3
|
0.5
|
4 to 60
|
2 to 13
|
H2O/CH3CN=25/75
|
Eluents:
Aqueous solutions of Acetonitrile (or Methanol) at any ratio, is used as eluent.
Any salts soluble in the solution above are available.