Skip to main content
Print

Equivalent Columns for Silica C18, C8 and CN

Record: 26


Category: Column Selection
Product:
Sample:


Question
Does Shodex have equivalent columns for silica C18, C8, and CN columns?

 

Answer

Unfortunately, the columns mentioned below are discontinued. However, we do still offer  similar column equivalent for silica columns such as the C18M 4D (4.6 x 150 mm) and C18M 4E (4.6 x 250 mm). We offer our UHPLC columns C18U 4D and C18U 2B columns as well.

Our HILIC series Asahipak NH2P and HILICpak VG series columns are a good, though not exact, alternative to the silica CN columns as these columns operate in HILIC mode primarily. They can be used in normal phase mode as well.

We strongly recommend our polymer-based C18 columns. The ODP series is more rugged and can handle high pH environments.

Additional Comments

Old Archived Information

1. C18 RP 18 – 5µm 125 x 4,0 mm. HPLC Reverse fase 100A poro, Area is 350m2/g , 21,0% carbon wich is an equivaken column with a HPLC EliteLechrom.

*Shodex C18-D (5um, 4.6 x 150, 17% C, A=320m2/g, 12nm A pore)
There will be less retention (less C load, but the analysis maybe bit longer, longer column length)

2. C18 RP18e – 5µm – 125 x 4,0mm. 120A pore size , 330m2/g Area , 17% de carbon. a pH bwt 1,5 to 10,5.

*RSpark RP18-413 (3.5 um, 4.6 x 150, no functional group – but will work like a reversed phase mode, 200 A pore)
Only reversed phase column that is usable under pH bt 1-13.
But since this is not modified with any carboxyl functional group, the separation performance may differ from expected RP analysis.

If the customer is not using mobile phase <2, ODP50 4D (5 um, 4.6 x 150 mm, 250 A pore, pH 2-13) can be recommended. This has octadecyl functional group. Also this has bigger particle size (fit to the request). 3. C18 RP18 – 5µm – 250 x 4,0mm. 100A pore , 350m2/g Area , 21,0% carbon. pH bwt 2,0 to 7,5. Equivalent to a HPLC Elite Le Chrom. *Asahipak ODP-50 4E (5 um, 4.6 x 250 mm, 250 A pore, pH 2-13) 4. C8 RP8e – 5µm – 125 x 4,0mm. 120A pre size , 330m2/g Area , 11,2% carbon pH bwt 1,5 to 10,5. *RSpark RP18-413 (3.5 um, 4.6 x 150, no functional group – but will work like a reversed phase mode, 200 A pore) Only reversed phase column that is usable under pH bt 1-13. But since this is not modified with any carboxyl functional group, the separation performance may differ from expected RP analysis. If the customer is not using mobile phase <2, Asahipak C8P-50 4D (5 um, 4.6 x 150 mm, 250 A pore, pH 2-13) can be recommended. This has octyl functional group. Also this has bigger particle size (fit to the request). 5. C8 RP8 – (5µm) 125 x 4,0 mm, 100A pore size , 350m2/g Area , 12,5% carbon. pH bwt 2,0 e 7,5. Equvalent to HPLC EliteLechrom. *Asahipak C8P-50 4D (5 um, 4.6 x 150 mm, 250 A pore, pH 2-13) 6. Silica Coluna with a ciano group – CN; 125x4mm – 5um: , 100A; Volumen= 1,25 ml/g; Área= 350m2/g;% carbon= 6,6%; Cobertura da superfície: 3,52 umol/m2; Efficiency : > 40.000 N/m – 15.000 N/m; pH: 2,0 a 7,5.

*Silica 5CN 4D (cyanopropyl functional group, 5 um, 4.6 x 150 mm, 100 A pore, pH 2-8, >48,000N/m)

7. Pré-colunas C18. sílica 5µm, 120A pore , 330m2/g Area específica, 3umol/m2 with 17% carbon . pH bwt 1,5 e 10,5.

8. Pré-colunas C18. sílica 5µm, 120A pore , 330m2/g Area específica, 3umol/m2 with 11.2% carbon . pH bwt 1,5 e 10,5.

*Are they talking about the Guard column? –also we do not have a guard (nor pre-column) for silica based columns…and I don’t think any silica column can work under pH 1.5…

9. Pré-colunas CN with ciano group 5µm, poro: 100A; Volumen: 1,25 ml/g; Área: 350m2/g; % Carbon: 6,6%; Eficiência: > 40.000 N/m – 15.000 N/m; bwt pH: 2,0 a 7,5.

*Again, we do not have Pre-column. Also for CN, we do not have a guard.