The Shodex Asahipak GF-310 HQ aqueous organic solvent column is a high-performance liquid chromatography (HPLC) column that offers high durability, superior resolution, and high throughput. It is designed to handle a wide range of applications, including the separation of small molecules and large biomolecules. This column is packed with a hydrophilic polyvinyl alcohol polymer gel that provides excellent stability in both aqueous and organic solvents, making it versatile and dependable. It also has a long lifespan and can be used for multiple runs without losing its performance. The Shodex Asahipak GF-310 HQ aqueous organic solvent column is an ideal choice for researchers and analysts who demand exceptional quality and reliability.

Asahipak GF-310 HQ
(Free FedEx 2-day shipping)The Shodex Asahipak GF-310 HQ aqueous organic solvent column is a high-performance liquid chromatography column suitable for separating small and large biomolecules.
| plate-number-tp-column | >19,000 |
|---|---|
| max-usable-flow-rate-ml-min | 1.0 |
| ph-range | 2 to 9 |
| size-i-d-x-length-mm | 7.5 x 300 |
| exclusion-limit-pullulan | 40,000 |
| pore-size-maximum | 400 |
| particle-size-um | 5 |
| max-pressure-mpa | 7.0 |
| shipping-solvent | CH3OH/H2O=30/70 |
| max-usable-temperature | 60 |
Questions & Troubleshooting
- Shodex SUGAR SH-Series Columns for Sugar and Organic…
- Shodex Column Recommendation for Sugar Analysis in…
- SEC Column for PEG and Hydrophilic Polymers Using…
- Shodex Column Recommendation for Short-Chain Fatty…
- Shodex KF Column Selection for Organic GPC Analysis…
- GPC Column for Polymers in THF and HPLC Column for…
- SEC Column Selection for Separating 20 kDa and 35…
- Shodex SEC Replacements for TSKgel G2000SWXL in…
- Shimadzu/Shodex/UC Davis
- Shodex Polymer-Based SEC Columns for Nanoparticles…
Related products
Related Applications
-
On-line Surfactant Removal (GF-4A)

Surfactants are often used to solubilize cell membrane and/or to prevent peptide/protein to be adsorbed on the container surface. However, the presence of surfactant may deteriorate LC column and LC/MS system, results in poor repeatability. By using MSpak GF-4A, surfactant […]
-
Relation of sample load and HETP with ovalbumin

Non-porous columns cannot be loaded with much sample compared with porous type columns. Please take care of sample amount. In the case of preparation, porous type is recommended. Max. amount of sample load (per column): DEAE3N-4T: 10 µg DEAE-825: 250 […]
-
Column Test Conditions (Ligand Exchange and Ion Exclusion Chromatography Columns)

Column Test Conditions for Ligand Exchange and Ion Exclusion Chromatography We are often asked “What standards should I run to assess the condition of my column?”. Well, here they are for all of our columns. We realize that chromatographers […]
-
Effects of Sample Preparation Solution on Sugar Separation (NH2P-50 4E)

The effects of sample preparation solution composition on HILIC mode sugar separation were studied with a polymer-based amino column, Asahipak NH2P-50 4E. The eluent used was H2O/CH3CN = 25/75. It was observed that the more deviation of the sample preparation […]