The Shodex™ preparative size reversed phase polymer ODP-50 10E. The relatively large pore size is suitable for the purification of amino acids, peptides, and proteins. Moreover, the rugged solid support is usable in a wide pH range from pH 2 to 13. Usable in 100 % water and buffer solution. Best used for the purification of basic substances.

Asahipak ODP-50 10E
(Free FedEx 2-day shipping)| max-pressure-mpa | 15 |
|---|---|
| particle-size-um | 5 |
| carbon-load | 17 |
| flow-rate-usual | 0.5 to 0.8 |
| functional-group | Octadecyl |
| size-i-d-x-length-mm | 10.0 x 250 |
| max-usable-flow-rate-ml-min | 1.5 |
| in-column-solvent | H₂O/CH₃CN (35/65) |
Questions & Troubleshooting
- Equivalent Columns for Silica C18, C8 and CN
- Preparative GPC Options for THF-Soluble Polymers…
- Equivalency Considerations Between ZORBAX GF-250 and…
- Separating Acidic Seaweed-Derived Sugars from Salt…
- SEC Column Selection for Separating 20 kDa and 35…
- 2011-06-15 (Wed) 22:32:37 Shodex Technical question
- Shodex Polymer-Based SEC Columns for Nanoparticles…
- Shodex SEC Replacements for TSKgel G2000SWXL in…
- C18 and C8 columns
- Column Selection for Sugar, Amino Sugar, and Amino…
Related products
Related Applications
-
Simultaneous Analysis of Nitrite and Ammonium Thiocyanate According to Japanese Testing Methods for Fertilizers (NH2P-50 4E)

Nitrite and ammonium thiocyanate (thiocyanate compounds) are known cause of plant growth disorders. According to Japanese Testing Methods for Fertilizers (2016*), “High-performance liquid chromatography method” under “5.8 Ammonium thiocyanate (thiocyanate compound)” and “5.9 Nitrite” should be carried out with a column […]
-
GPC Column Recommendation for ~100 kDa Polymers Using DMF

Record: 672 Category: Column SelectionProduct: KD-803Sample: Polymer QuestionA customer is analyzing a polymer with an approximate molecular weight of ~100 kDa using dimethylformamide (DMF) as the solvent. Do you have a Shodex column recommendation? Answer Yes. For gel permeation chromatography […]
-
Looking for column with packing material PbO, PbO2 and PbSO4

Record: 24 Category: Column Selection Product: Sample: flotation reagents Question can custom make PbO2, PbSO4, and PbO columns? Answer So to summarize your analysis need: You are planning to test the adsorption between (PbO2,PbSO4,PbO) and 7 analytes you […]
-
IC SI-90 4E

IC SI-90 4E Troubleshooting Tips To control ion elution shifts on the Shodex IC SI-90 4E anion analysis column, you must strictly manage column temperature and eluent composition, as these directly impact retention and elution order (especially for polarizable ions […]