• Relatively large pore size is suitable for the analysis of amino acids, peptides, and proteins
• Usable in a wide pH range from pH 2 to 13
• Usable in 100 % water and buffer solution
• Best used for the analysis of basic substances
• ODP-50 fulfills USP-NF L67 requirements

ODP-50 2D
(Free FedEx 2-day shipping)Suitable for the analysis of amino acids, peptides, and proteins. Usable in a wide pH range from pH 2 to 13. ODP-50 fulfills USP-NF L67 requirements.
| plate-number-tp-column | >5,000 |
|---|---|
| base-material | Polyvinyl Alcohol |
| particle-size-um | 5 |
| pore-size-average-a | 250 |
| size-i-d-x-length-mm | 2.0 x 150 |
| carbon-load | 17 |
| flow-rate-usual | 0.3 to 0.6 |
Questions & Troubleshooting
- Equivalent Columns for Silica C18, C8 and CN
- Equivalency Considerations Between ZORBAX GF-250 and…
- Column Selection for Phenolic Acids and…
- 2011-06-15 (Wed) 22:32:37 Shodex Technical question
- SEC Column Selection for Separating 20 kDa and 35…
- Shodex Polymer-Based SEC Columns for Nanoparticles…
- Shodex SEC Replacements for TSKgel G2000SWXL in…
- Largest Pore Size Shodex SEC Columns for Acrylic…
- Peeke Scientific Inquiry
- Protein KW column and Your shodex US contact
Related products
Related Applications
-
Simultaneous Analysis of Nitrite and Ammonium Thiocyanate According to Japanese Testing Methods for Fertilizers (NH2P-50 4E)

Nitrite and ammonium thiocyanate (thiocyanate compounds) are known cause of plant growth disorders. According to Japanese Testing Methods for Fertilizers (2016*), “High-performance liquid chromatography method” under “5.8 Ammonium thiocyanate (thiocyanate compound)” and “5.9 Nitrite” should be carried out with a column […]
-
Relation of sample load and HETP with ovalbumin

Non-porous columns cannot be loaded with much sample compared with porous type columns. Please take care of sample amount. In the case of preparation, porous type is recommended. Max. amount of sample load (per column): DEAE3N-4T: 10 µg DEAE-825: 250 […]
-
LC/MS/MS Analysis of Saccharides (VG-50 2D)

HILICpak VG-50 2D, a polymer based amino column, was used for LC/MS/MS analysis of saccharides and sugar alcohols. Adding ammonia to the eluent enhances the ionization of saccharides, and is effective for high sensitive detection. Sample : 50ng/mL each (in […]
-
Elution Volume of Saccharides (VG-25 4D)

Below table summarizes elution volumes of saccharides using HILICpak VG-25 4D, a polymer-based amino column. Elution values shown are the peak top positions, please contact us to request a chromatogram if you would like to see their elution patterns. Click […]